--- title: "TS2050-ZX Modem Modification Project" type: "article" slug: "ts2050-zx-modem-modification-project" url: "http://localhost/article/ts2050-zx-modem-modification-project/" markdown_url: "http://localhost/article/ts2050-zx-modem-modification-project.md" published_at: "2026-11-03T17:29:34+00:00" modified_at: "2026-11-03T21:15:07+00:00" featured_image: url: "http://localhost/wp-content/uploads/2022/04/20230809-041332.jpg" excerpt: "OBJECTIVE: This Hardware/Software modification will allow the user to operate the Westridge TS2050 Modem with the Sinclair ZX Interface 1 and Microdrives. WHY IT DID NOT WORK: The reason that the TS2050 modem WILL NOT work \"as-is\" is because of an \"address conflict\" between the Interface-1 and the TS2050. That is the BASIC reason at…" post_tag: - name: "Full Text" slug: "fulltext" taxonomy: "post_tag" url: "http://localhost/tag/fulltext/" - name: "Hardware project" slug: "hardware-project" taxonomy: "post_tag" url: "http://localhost/tag/hardware-project/" - name: "MTERM" slug: "mterm" taxonomy: "post_tag" url: "http://localhost/tag/mterm/" - name: "Telecomputing" slug: "telecomputing" taxonomy: "post_tag" url: "http://localhost/tag/telecomputing/" - name: "TS 2050" slug: "ts-2050" taxonomy: "post_tag" url: "http://localhost/tag/ts-2050/" - name: "TS 2068" slug: "ts2068" taxonomy: "post_tag" url: "http://localhost/tag/ts2068/" - name: "Westridge Communications" slug: "westridge-communications" taxonomy: "post_tag" url: "http://localhost/tag/westridge-communications/" - name: "ZX Spectrum" slug: "zx-spectrum" taxonomy: "post_tag" url: "http://localhost/tag/zx-spectrum/" model: - name: "Sinclair ZX Spectrum" slug: "zxspectrum" taxonomy: "model" url: "http://localhost/model/zxspectrum/" - name: "Timex/Sinclair 2068" slug: "ts-2068" taxonomy: "model" url: "http://localhost/model/ts-2068/" indiv: - name: "Dave Clifford" slug: "dave-clifford" taxonomy: "indiv" url: "http://localhost/indiv/dave-clifford/" publication_r: id: 10277 title: "Time Designs Magazine" type: "periodical" url: "http://localhost/periodical/time-designs-magazine/" authors: "Dave Clifford" volume: "4" issue: "1" issues_articles: - id: 36805 title: "Time Designs Magazine v4 n1" type: "issue" url: "http://localhost/issue/time-designs-magazine-v4-n6-2/" pages: "unnumbered (PDF 23-24)" pubdate: "November/December 1987" archive_link: false --- # TS2050-ZX Modem Modification Project OBJECTIVE: This Hardware/Software modification will allow the user to operate the [Westridge TS2050 Modem](http://localhost/product/westridge-2050-modem/) with the Sinclair ZX Interface 1 and Microdrives. WHY IT DID NOT WORK: The reason that the TS2050 modem WILL NOT work “as-is” is because of an “address conflict” between the Interface-1 and the TS2050. That is the BASIC reason at least, but it gets slightly more involved when selecting a new Port Address to operate the modem from. For a close-up discussion as to how to avoid this problem, you should consult a copy of “The Spectrum Hardware Manual” by Adrian Dickens (published by [Melbourne House](http://localhost/company/melbourne-house-publishers/)). If you have access to a copy, read the section in Chapt. 14 called “Adding 128 I/O Ports”. For those of you who are un-able to obtain a copy, I will quote a few words from that section: “In the Spectrum a very simple form of decoding I/O port addresses is used. A0 is used to select the ULA, A1 the ZX printer and A3, A4, A5 the microdrives and RS-232 interface. No more than one of these address lines should ever be at logic 0 during an I/O operation. If they are then several devices will try to use the data bus simultaneously. Homebrew circuits therefore only have address lines A5, A6 and A7 available to select them”. The stock TS2050 modem uses PORT $73 (HEX) or 115 (DEC) for DATA I/O and PORT $77 (HEX) or 119 (DEC) for CONTROL and STATUS I/O. Convert these numbers to BINARY and you can see where the “rub” is: ``` ADDRESS LINES A7 A6 A5 A4 A3 A2 A1 A0 PORT $73 (HEX) = 0 1 1 1 0 1 1 1 PORT $77 (HEX) = 0 1 1 1 0 0 1 1 * * * = Conflict on BOTH addresses! ``` NOW THE “PATCH”: Now that we understand what the problem is and we have an idea of what address lines we can not use (A0 thru A4), we now know the “range” for addresses we can employ. After you install this modification to your TS2050 it will allow you to change the port addresses that the modem uses to those that are a lot more agreeable to the ZX Interface-1 and here is what the new port addresses will be: ``` DATA PORT = $3F (HEX) or 63 (DEC) CONTROL/STATUS PORT = $7F (HEX) or 127 (DEC) ``` And in BINARY… ``` ADDRESS LINES A7 A6 A5 A4 A3 A2 A1 A0 PORT $3F (HEX) = 0 0 1 1 1 1 1 1 PORT $7F (HEX) = 0 1 1 1 1 1 1 1 ``` NOW OFF TO THE TOOL CRIB. HERE’S WHAT WE WILL NEED: A Phillips screwdriver (to take the modem case apart), a 25 to 30 watt pencil soldering iron, a pair of needle-nose pliers and diagonal cutters, an X-Acto knife with a nice sharp blade, a drill with a bit that is of suitable size to mount a toggle switch (optional), some solder (quality 60/40 rosin core type), a small wire brush or flux remover, and don’t forget some eye protection! AND THE PARTS DEPARTMENT: a) 1 three pole double throw switch (Radio Shack #275-6661). b) 7 pieces of small-gauge “hook-up” wire, approx. 6″ long, and you should obtain 7 different colors. The best stuff to use is a length of “rainbow” ribbon cable and separate the conductors into individual wires. The schematic is marked with the first 7 colors that you will normally find. They are Brown, Red, Orange, Yellow, Green, Blue and Violet. (Note: If you decide on a color scheme of your own, be careful! If you make a mistake it could cost you a computer or modem or both.) [![Drawing A. Sub-miniature 3PDT toggle switch wiring](http://localhost/wp-content/uploads/2026/11/timedesigns-new-ts2050-zx-modem-modification-project-1-1024x594.png)](http://localhost/wp-content/uploads/2026/11/timedesigns-new-ts2050-zx-modem-modification-project-1.png)Drawing A. Sub-miniature 3PDT toggle switch wiring READY FOR ASSEMBLY: Now we are ready to open the modem. Carefully remove the case and place the P.C. card on the work bench “solder-side” up. Prepare the toggle switch as shown in Drawing “A”. After the switch is complete, study Drawing “B” and “C” (also the schematic) to determine what P.C. conductors are to be cut and where to solder the wires from the switch. When soldering, apply just enough heat and solder to do the job. Now you can select a position on the rear or front panel to mount your toggle switch. Be sure that it won’t get in the way of the P.C. card or a component on the card when you re-assemble the modem. Check and re-check your assembly! If it all looks good, let’s go for a test. Can you remember which position the switch is in for “normal mode” and which is the “2050 ZX mode”? First let’s try [MTERM II](http://localhost/product/mterm-ii-tape/) (terminal software program) in “normal mode” and see if we are functional (don’t connect the Interface-1, it won’t work). If everything is normal, then we are all set to try the “2050 ZX mode”. Before we do, we must customize a copy of MTERM II with some simple software POKEs so it will communicate with the TS2050 in this mode. MTERM II TERMINAL SOFTWARE MODIFICATION: Set up your TS2068 for Spectrum Mode (using an Emulator or Romswitch) and switch it on. Execute CLEAR 53950 and press ENTER. Execute LOAD “mterm”CODE and press ENTER. (Note: If you have a BASIC LOADer that auto-runs MTERM or contains an auto-dialer, remember to change the IN/OUT addresses to the new ones. Also if you are running a print driver that is “port dependant” for data I/O to the TS2050, they too have to be changed. Because of the diverse configurations that are available, you are on your own in this department.) Execute the following POKEs: ``` ------------------------------------------------------------- I/O Port Addresses and their NEW values. ------------------------------------------------------------- HEX DEC VAL HEX DEC VAL E712 = 59154,127 E719 = 59161,63 E724 = 59172,127 E735 = 59189,63 E73C = 59196,127 E73E = 59198,127 E740 = 59200,127 E744 = 59204,127 E74A = 59210,127 E752 = 59218,127 D6A6 = 54950,127 D69A = 54938,127 D67F = 54911,127 D5E1 = 54753,127 ``` The following two POKEs will allow you to EXIT to BASIC while in Spectrum mode and not crash: POKE 54554,207 POKE 54555,255 Now let’s save your “Spectrum Friendly” version of MTERM II to tape. Execute SAVE “mtermzx”CODE 54016,7721 and press ENTER. For the Microdrives, execute SAVE*”m”;1;”mtermzx”CODE 54016,7721 and press ENTER. That’s it…now you can customize MTERM to your taste. The I/O ports are as follows: DATA = 63 (DEC) CONTROL/STATUS = 127 (DEC) [![Drawing B. TS2050 P.C. card, solder side, with cut points and wire colors](http://localhost/wp-content/uploads/2026/11/timedesigns-new-ts2050-zx-modem-modification-project-2-1024x955.png)](http://localhost/wp-content/uploads/2026/11/timedesigns-new-ts2050-zx-modem-modification-project-2.png)Drawing B. TS2050 P.C. card, solder side, with cut points and wire colors Cut the P.C. “lands” (conductive foil) at the points indicated by the ‘Cut–>’ flags. Solder the proper wire from the switch assembly as indicated by the ‘COLOR’ flags. CHECK YOUR CONNECTIONS! PROJECT SYNOPSIS: MTERM II will function just as it did when running on the standard TS2068 except when you “EXIT to BASIC” MTERM’s main menu will still be present. To clear the screen just hit the ENTER key and you will have a clear screen with the “K” cursor ready for your commands. Also, with the ZX Interface-1 attached the “extended” BASIC commands and error codes are on-line as well. For example, with Interface-1 attached and you do PRINT USR 54016 to enter MTERM and then EXIT to BASIC, you will see the “Program finished, 0:1” message at the bottom of the screen. And the Buffer Counter will display a slightly different value with Interface-1 attached (30153) as without. [![Drawing C. Modified TS2050 schematic with switch](http://localhost/wp-content/uploads/2026/11/timedesigns-new-ts2050-zx-modem-modification-project-3-706x1024.png)](http://localhost/wp-content/uploads/2026/11/timedesigns-new-ts2050-zx-modem-modification-project-3.png)Drawing C. Modified TS2050 schematic with switch The port addresses that I selected for this project are (to the best of my knowlege) not used by any of the “standard” peripherals associated with the Spectrum computer. If you have a device (like the [Aerco](http://localhost/company/aerco/) parallel I/F) that shares one of the addresses then you may have a problem. You can change the addresses on the TS2050 to just about anything you want. Just remember the binary decoding that the Spectrum and Interface-1 employs and you should have no problems selecting a second address pair. WHY A SWITCH?? You do not need the switch. The switch allows you to quickly configure the TS2050 to run in Spectrum mode or on say a TS1000/TS1500 with a minimum of components. You can hard-wire your modem for the new addresses and after POKEing the new values into MTERM for Spectrum mode, POKE the same values into a copy of MTERM for the TS2068 (just don’t include the two POKEs at 54554 and 54555). CONCLUSION: Many have enjoyed this modification for months and I hope you will too. If there is enough interest, I have a modification that will allow the TS2050 to dial up the U.K., using the CCITT v.21 protocol. [![Drawing D. TS2050 P.C. card, component side](http://localhost/wp-content/uploads/2026/11/timedesigns-new-ts2050-zx-modem-modification-project-4-1024x387.png)](http://localhost/wp-content/uploads/2026/11/timedesigns-new-ts2050-zx-modem-modification-project-4.png)Drawing D. TS2050 P.C. card, component side