--- title: "Letter Quality Printing" type: "article" slug: "letter-quality-printing" url: "http://localhost/article/letter-quality-printing/" markdown_url: "http://localhost/article/letter-quality-printing.md" published_at: "2026-11-21T22:03:25+00:00" modified_at: "2026-11-21T22:03:25+00:00" featured_image: url: "http://localhost/wp-content/uploads/2022/04/20230809-041332.jpg" excerpt: "The Panasonic RK-T25 is a formed character printer/typewritter which can be purchased for around $189. I asked Panasonic if it could be used as a communications terminal, but, as you can see, it can't. I have to respect Panasonics wishes and not publish the DB9 printout they sent me, I can tell you though, that…" post_tag: - name: "Full Text" slug: "fulltext" taxonomy: "post_tag" url: "http://localhost/tag/fulltext/" indiv: - name: "Paul Donnelly" slug: "paul-donnelly" taxonomy: "indiv" url: "http://localhost/indiv/paul-donnelly/" genre: - name: "Printer" slug: "printer" taxonomy: "genre" url: "http://localhost/type/printer/" publication_r: id: 38992 title: "LISTing Newsletter" type: "periodical" url: "http://localhost/periodical/listing-newsletter/" authors: "Paul Donnelly" issues_articles: - id: 40181 title: "LISTing Newsletter March – April 1987" type: "issue" url: "http://localhost/issue/listing-newsletter-march-april-1987/" pages: "8" pubdate: "March - April 1987" archive_link: false --- # Letter Quality Printing The Panasonic RK-T25 is a formed character printer/typewritter which can be purchased for around $189. I asked Panasonic if it could be used as a communications terminal, but, as you can see, it can’t. I have to respect Panasonics wishes and not publish the DB9 printout they sent me, I can tell you though, that only pins 1 through 4, and 9 (ground) are used, and that 1,2 and 3 are not data lines. This is not an RS 232 port, but uses TTL signal levels. Do not make a direct connection to the port with an RS 232 line. It might work, but the chances of ruining the printer on your port are too high to risk it. Instead, build your own RS 232 interface – the chip you need is available from Radio Shack for $2.00 or so. It is called an RS 232 driver and converts TTL (Transistor-Transistor Logic) signals from the 0 to + 5 volt range to the -10 volt to + 10 volt range (typical) which characterizes RS 232 signals. The RP-K1000 interface costs about 50 dollars. Best bet, if you want an interface, is to buy their S & P converter for about $100. That way, you can use this typewritter with either an RS 232 or Centronics port. *** Matsushita Services Company Division of Matsushita Electric Corporation of America 50 Meadowland Parkway, Secaucus, New Jersey 07094 201 348 7000 Executive Offices November 18, 1986 P. Donnelly Centerport, NY 11721 Dear Mr. Donnelly: We referred your letter to our engineering staff for consideration. Attached, please find information on the TTTL signal. The RK-T25 will receive communication and cannot be used as a communication terminal. The demonstration is stored in ROM and cannot be reused. For your convenience we have listed information on obtaining a service manual. RK-T25 Service Manual – GAD86045 Technical Guide for Wheel Motor Drive Circuit – GAD8608610TD Technical Guide for RK-T40 – 85042215G0 (Useful information regarding RK-T25 in the Technical Guides.) Service manual contains parts list, schematic and adjustments. Technical guides contain circuit descriptions. We recommend using the RP-K100 Interface Adaptor because we cannot assure proper operation if you build your own interface. Please keep this information for your own personal use and we request not publishing the DB-9 pinout in your newsletter. I hope these explanations have been helpful. If you have any further questions, please contact me. Very truly yours, Regina Hinton Consumer Affairs Department RH/js [![Panasonic/Technics/Quasar interface timing diagram: ON LINE, DATA, STROBE, ACK](http://localhost/wp-content/uploads/2026/11/listing-new-1987-03-04-letter-quality-printing-1-1024x368.png)](http://localhost/wp-content/uploads/2026/11/listing-new-1987-03-04-letter-quality-printing-1.png)Panasonic/Technics/Quasar interface timing diagram: ON LINE, DATA, STROBE, ACK *** Centerport, N.Y. 11721 Panasonic Dear Sir: I recently purchased a Panasonic RK-T25 electronic typewriter at LaBelle Camera in Syosset, New York. The RK-T25 was selected because of its advanced features, reasonable price and presumed Panasonic Quality. Unfortunately, as I am sure the staff at LaBelle will confirm, I had to return two RK-T25’s before getting one which worked properly. The two defective machines would randomly print letters out of line. Fortunately, after 3 trips to the store (1/2 hour each way) they were able to find a good machine. The third T-25 works fine, but frankly, I was a bit surprised to find two defective machines. One of the features which influenced my decision to choose the T-25 over competitors models was the computer interface. I have a Brother EP-44, and found the RS 232 port on that machine to be quite useful. The EP-44 is, however, not a formed character printer like the RK-T-25. In reviewing the manual which came with the T-25, though, I find no reference to the pin-out on the DB-9 connector. Page 48 is ambiguous enough that it appears to say only a cable (RP-K111 or K110) is required for RS 232 operation. On page 59, we see the RP-K100, which appears to be a serial-to parrallel converter. The pictures of the RP-K100 & 111 show serial cables with 25 pin connectors at each end, yet page 48 indicates the serial cable may be all one needs to use the T-25 on an Apple or IBM computer. Can you please provide more detail on your interface? Specifically I would like to know: 1) Pinout for the DB-9 connector 2) Signal type & levels to be expected (e.g., are they TTL, CMOS or RS 232) for each pin. 3) Current cost of the RP-K 110, K111, K100. 4) Whether the T25 can be used as a communication terminal. (The EP-44 can) That is, is the interface port actually one way? 5) Is a schematic or tech/repair manual available for the RK-T25? Finally, I would like to know if there is a way to reutilize the demo space. This appears inaccessible to the user. If it is battery backed-up CMOS, I would like to be able to use it (as a 10th phrase for example). If PROM, it might still be useful, to those with an EPROM programer, as a place to put “boiler plate” (eg, return address, stationery letter head, etc.). Can you tell me if there is a way to re-use this area? I look forward to your response and thank you in advance for your help. Please advise if you have any objection to our publishing the DB-9 pinout in our user group newsletter. Very truly ypurs, P. Donnelly